Durable IK06 LED panel lights
SGSLight TLP LED panel series have been tested by TUV and rated to be IK06.
What is the IK rating?
The IEC 62262 IK rating classifies the level of protection that electrical appliances provide against mechanic impacts from outside. IK rating is an international numeric classification for the degrees of protection provided by enclosures for electrical equipment against external mechanical impacts. It provides a means of specifying the capacity of an enclosure to protect its contents from external impacts.
IK | MECHANICAL PROTECTION | |
0 | No protection | |
1 | Impact energy 0.150 Joules | |
2 | Impact energy 0.200 Joules | |
3 | Impact energy 0.350 Joules | |
4 | Impact energy 0.500 Joules | |
5 | Impact energy 0.700 Joules | |
6 | Impact energy 1.00 Joules | |
7 | Impact energy 2.00 Joules | |
8 | Impact energy 5.00 Joules | |
9 | Impact energy 10.00 Joules | |
10 | Impact energy 20.00 Joules |
TUV IK06 test
SGSLight IK06 LED panel is tested by TUV laboratory according to IEC 62262:2002 and Clause 4.13.1 of EN 60598-1:2008+A11. The IK06 TUV testing report is here.
4.13.1 Luminaires shall have adequate mechanical strength and be so constructed as to be safe after such rough handling as may be expected in normal use.
Compliance is checked by applying blows to the sample by means of the spring-operated impact test apparatus specified in IEC 60068-2-75 or by other suitable means giving equivalent results.